Place of Origin: | China |
ब्रांड नाम: | KRIPAL |
प्रमाणन: | CE |
Model Number: | UKL1 |
Minimum Order Quantity: | 1000 pcs |
---|---|
मूल्य: | negotiable |
Packaging Details: | 12 poles packed in one small box and then in carton |
Delivery Time: | 20 days and depends on ordering quantity |
Payment Terms: | T/T, L/C |
Supply Ability: | 200000 pcs per month |
Poles available: | 2P, 4P | Ampere: | 16A 25A 40A 63A |
---|---|---|---|
Residual protection: | Yes | Type: | mini circuit breaker |
leakage current: | 10 30 100 300 500mA | Standard: | IEC1008 EN61008 |
हाई लाइट: | छोटे सर्किट ब्रेकर,माइक्रो सर्किट ब्रेकर |
Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A
KRIPAL has the design patent for these items
A residual-current device (RCD), or residual-current circuit breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a person who is grounded and accidentally touching the energized part of the circuit. A lethal shock can result from these conditions. RCCBs are designed to disconnect quickly enough to prevent injury caused by such shocks. They are not intended to provide protection against overcurrent (overload) or all short-circuit conditions.
Techinical data:
A. Conform to standard: GB16916.1
B. Rated voltage (Ue): 230V/400V; 50/60Hz
C. Rated current (A): 16, 25, 40, 63 A (2 poles and 4poles)
D. Rated leakage current: 10, 30, 100, 300, 500Ma
E. Electric life: ≥ 4000 times (on-off)
F. Mechanical life: ≥ 2000 times (on-off)
G. Case protection grade: IP40 after installing
Mechanical parameter
A. Installation mode: At the DIN rail of standard IEC
B. Terminal wiring capability: Conductor 1-25 mm
C. Width of shell: 2 poles 36mm; 4 poles 72 mm
Main characteristic
A. Various current specifications of leakage action ca easily ensure selective protection.
B. Inaccurate action resulting form the switch operation of electronic equipment can be avoided
C. Unless specified otherwise, the width of two-poles switch is two modules, four-poles(3P+N) is four modules
Specifications:
Technology Specification & Electrical Specification | |
Electric standard | IEC1008 EN61008 |
Trip time | Non-time delay; Minimal 10ms time delay |
Rated voltage | 230V/400V |
Rated surplus operating current | 10; 30; 100; 300mA, 500mA |
Selection grade | 3 |
Poles | 2pole 4pole |
Rated current | 16A, 25A, 40A, 63A |
Tripping character | B, C, D characteristic curve |
Terminal wiring | conductor 1-25 mm2 |
Environment capability | According to the IEC 1008 standard |
Case protection grade | IP40 after installation |
Electric life | Not less than 4000 times of breaking and closing |
Mechanical life | Not less than 2000 times of breaking and closing |
Mechanical Parameter | |
Installation mode | Installation at the DIN guide rail of 35mm |
Terminal block capacity | General thickness 0.8-2mm |
Main benefits:
High quality
Complete range
Instantaneous tripping current:
International Standard--- IEC 60898-1 and European Standard EN 60898-1 define the rated current In of a circuit breaker for low voltage distribution applications as the maximum current that the breaker is designed to carry continuously (at an ambient air temperature of 30 °C). The commonly-available preferred values for the rated current are 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A,[5] and 125 A (Renard series, slightly modified to include current limit of British BS 1363 sockets). The circuit breaker is labeled with the rated current in amperes, but without the unit symbol "A". Instead, the ampere figure is preceded by a letter "B", "C" or "D", which indicates the instantaneous tripping current — that is, the minimum value of current that causes the circuit breaker to trip without intentional time delay (i.e., in less than 100 ms), expressed in terms of In:
Type |
Instantaneous tripping current |
B |
above 3 In up to and including 5 In |
C |
above 5 In up to and including 10 In |
D |
above 10 In up to and including 20 In |
व्यक्ति से संपर्क करें: Allen
IP66 आईपी 67 32 Amp रोटरी अलगाव स्विच डिस्कनेक्टर सौर पीवी सिस्टम के लिए
Weatherproof 100 Amp Disconnect Switch with 1NO+1NC For Rotary Isolating
Waterproof IP65 Rotary Isolator Switch / 2 Pole 3 Pole Disconnect Switch
Blue IP44 Industrial Power Socket Pin And Sleeve Electrical Connectors
Pin and Sleeve Plug Industrial Power Socket IP44 IP67 Coupler Connector
Mechanical Interlock Industrial Power Switched Sockets , Single / Three Phase
तीन चरण अग्निरोधी एन्क्लसौएर एसी कंप्रेसर सम्प्रेषक और रिले 180 ए
इलेक्ट्रिक स्विच स्विच स्विच एसी संपर्कक चुंबकीय 9 ए 12 ए 18 ए 22 ए
जीएमसी 4 पी मिनी मैकेनिकल इंटरलॉकिंग होम एसी संपर्ककर्ता जीएमसी 9 एमआर 9 ए 3 चरण संपर्ककर्ता
9 ए 12 ए 18 ए 22 ए सिंगल फेज डीओएल स्टार्टर एसी संपर्ककर्ता निश्चित प्रयोजन