उत्पाद विवरण:
Place of Origin: China
ब्रांड नाम: KRIPAL
प्रमाणन: CE
Model Number: UKL1
भुगतान & नौवहन नियमों:
Minimum Order Quantity: 1000 pcs
मूल्य: negotiable
Packaging Details: 12 poles packed in one small box and then in carton
Delivery Time: 20 days and depends on ordering quantity
Payment Terms: T/T, L/C
Supply Ability: 200000 pcs per month
संपर्क करें
विस्तृत उत्पाद विवरण
Poles available: 2P, 4P Ampere: 16A 25A 40A 63A
Residual protection: Yes Type: mini circuit breaker
leakage current: 10 30 100 300 500mA Standard: IEC1008 EN61008
हाई लाइट:

छोटे सर्किट ब्रेकर

,

माइक्रो सर्किट ब्रेकर

 

Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A


 

KRIPAL has the design patent for these items 


A residual-current device (RCD), or residual-current circuit breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a person who is grounded and accidentally touching the energized part of the circuit. A lethal shock can result from these conditions. RCCBs are designed to disconnect quickly enough to prevent injury caused by such shocks. They are not intended to provide protection against overcurrent (overload) or all short-circuit conditions.
 

 

Techinical data:


A. Conform to standard: GB16916.1
B. Rated voltage (Ue): 230V/400V; 50/60Hz
C. Rated current (A): 16, 25, 40, 63 A (2 poles and 4poles)
D. Rated leakage current: 10, 30, 100, 300, 500Ma
E. Electric life: ≥ 4000 times (on-off)
F. Mechanical life: ≥ 2000 times (on-off)
G. Case protection grade: IP40 after installing

 


Mechanical parameter

A. Installation mode: At the DIN rail of standard IEC
B. Terminal wiring capability: Conductor 1-25 mm
C. Width of shell: 2 poles 36mm; 4 poles 72 mm

 


Main characteristic

A. Various current specifications of leakage action ca easily ensure selective protection.
B. Inaccurate action resulting form the switch operation of electronic equipment can be avoided
C. Unless specified otherwise, the width of two-poles switch is two modules, four-poles(3P+N) is four modules
 


Specifications:

 
Technology Specification & Electrical Specification
Electric standard IEC1008 EN61008
Trip time Non-time delay; Minimal 10ms time delay
Rated voltage  230V/400V
Rated surplus operating current 10; 30; 100; 300mA, 500mA
Selection grade 3
Poles  2pole 4pole
Rated current 16A, 25A, 40A, 63A
Tripping character B, C, D characteristic curve
Terminal wiring  conductor 1-25 mm2
Environment  capability According to the IEC 1008 standard
Case protection grade IP40 after installation
Electric life Not less than 4000 times of breaking and closing
Mechanical life Not less than 2000 times of breaking and closing
Mechanical Parameter
Installation mode Installation at the DIN guide rail of 35mm
Terminal block capacity General thickness 0.8-2mm

 
  
Main benefits:
  
High quality
Complete range
 

Instantaneous tripping current:
 
International Standard--- IEC 60898-1 and European Standard EN 60898-1 define the rated current In of a circuit breaker for low voltage distribution applications as the maximum current that the breaker is designed to carry continuously (at an ambient air temperature of 30 °C). The commonly-available preferred values for the rated current are 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A,[5] and 125 A (Renard series, slightly modified to include current limit of British BS 1363 sockets). The circuit breaker is labeled with the rated current in amperes, but without the unit symbol "A". Instead, the ampere figure is preceded by a letter "B", "C" or "D", which indicates the instantaneous tripping current — that is, the minimum value of current that causes the circuit breaker to trip without intentional time delay (i.e., in less than 100 ms), expressed in terms of In:
 

    Type

Instantaneous tripping current

       B

above 3 In up to and including 5 In

       C

above 5 In up to and including 10 In

       D

above 10 In up to and including 20 In

 

सम्पर्क करने का विवरण
Zhejiang KRIPAL Electric Co., Ltd.

व्यक्ति से संपर्क करें: Allen

हम करने के लिए सीधे अपनी जांच भेजें
सर्वश्रेष्ठ उत्पादों
अन्य उत्पादों
रोटरी अलगाव स्विच

IP66 आईपी 67 32 Amp रोटरी अलगाव स्विच डिस्कनेक्टर सौर पीवी सिस्टम के लिए

सेमको, वीडीई, सीसीसी, सीई आईपी 65 2 ~ 5 पी 10 ए ~ 150 ए रोटरी आइसोलेटर स्विच विद्युत अलगाव स्विच पनरोक स्विच

Weatherproof 100 Amp Disconnect Switch with 1NO+1NC For Rotary Isolating

Waterproof IP65 Rotary Isolator Switch / 2 Pole 3 Pole Disconnect Switch

औद्योगिक पावर सॉकेट

Blue IP44 Industrial Power Socket Pin And Sleeve Electrical Connectors

Pin and Sleeve Plug Industrial Power Socket IP44 IP67 Coupler Connector

कोण अंदरूनी झुकाव 20 डिग्री आईपी 44 औद्योगिक पावर सॉकेट एकल या तीन चरण 16 ए, 32 ए, 63 ए 220V-250V; 380V-415V

Mechanical Interlock Industrial Power Switched Sockets , Single / Three Phase

एसी संपर्ककर्ता

तीन चरण अग्निरोधी एन्क्लसौएर एसी कंप्रेसर सम्प्रेषक और रिले 180 ए

इलेक्ट्रिक स्विच स्विच स्विच एसी संपर्कक चुंबकीय 9 ए 12 ए 18 ए 22 ए

जीएमसी 4 पी मिनी मैकेनिकल इंटरलॉकिंग होम एसी संपर्ककर्ता जीएमसी 9 एमआर 9 ए 3 चरण संपर्ककर्ता

9 ए 12 ए 18 ए 22 ए सिंगल फेज डीओएल स्टार्टर एसी संपर्ककर्ता निश्चित प्रयोजन

एक बोली का अनुरोध
Privacy Policy चीन अच्छा गुणवत्ता रोटरी अलगाव स्विच आपूर्तिकर्ता. © 2015 - 2022 industrialswitchsocket.com. All Rights Reserved.